Current Source Active Filter with Control Cabinet Enclosures in Power Quality Improvement in 3 Phase System

Type: Polypropylene Capacitor
Application: General Purpose, AC / Motor, Power
Packaging Type: Surface Mount
Capacitance: 50-100uf
Structure: Fixed Capacitor
Manufacturing Material: Polypropylene

Products Details

Basic Info.

Model NO.
APF-200AMP
Electrolyte
Electrolytic
Usage
Low Frequency Coupling, Filter
Tuning
Polystyrene Capacitor
Filter
Aluminum Electrolytic Capacitor
Phase
3-Phase 4-Wire; 3-Phase 3-Wire
Compensation Current
30A~150A
Rated Voltage
AC 400/690V(± 15%)
Harmonic Filter Rate
>97%
Installation Method
Rack-Mounted or Wall-Mounted
Parallel Operation
up to 8 Modules in Parallel
Transport Package
Pallet
Specification
CE ROHS
Trademark
OEM
Origin
Zhejiang Yueqing
HS Code
8504409999
Production Capacity
1000PCS/ Month

Product Description

APF 50AH active power filter for power capacitor substation Active Harmonic Filter with RS232/485
 A large number of high-tech operations have used a large number of variable frequency speed control devices in the entire production process from spinning to weaving, which has led to more and more power quality problems and harmonics in power systems, and has caused a lot of disadvantages to the production line. Causes the production line to have nylon chips, sizing machines, yarn doubling machines, automatic winders, combers, carding equipment, and tampers to use the automatic control equipment and power electronics to prevent the heating temperature from being controlled, resulting in serious product quality The decline will cause huge economic losses to the company; the electrical components such as transformers and busbars in the power distribution room will be severely hotted, causing great potential risks.

Introduction
  The active power filter (APF) is mainly composed of controller, isolation switch (circuit breaker), contactor, IGBT, driving circuit, protection system, fuse, connection reactor, DC capacitor, etc. The controller measures phase A, C reactive power(current), produces control signal, drives IGBT on/off and produces harmonic and reactive current same as system harmonic current but in opposite phase to filter system harmonic, reduce reactive power and keep system power factor approximately at 1.
    Our APF equipment is module structure,there are two types Wall Mounted and cabient mounted.The Wall Mounted type is preferred to be used in equipment improvement which is very conveninet to install.  
The Sanhe Modular Active Harmonic Filter series are suitable for applications of all types, providing harmonic mitigation, load balancing and step-less reactive power compensation for inductive and capacitor loads.  
 
Main Parameter
Rated voltage: 0.4kV,0.69kV
Frequency: 45Hz ~ 63Hz
Three level topology and high efficiency up to 97%
Filtering capacity: THDi (current distortion rate) < 5%
Response time: less than 15ms
Communication interface: RS485, network port,Wi-Fi

Feature
Harmonic, dynamic reactive power and imbalance compensation mode available.
Compact and reasonable structure, flexible installation.
Combination of FFT and instantaneous power algorithm available.
3DSP+CPLD control mode
2nd ~50th harmonic can be compensated simultaneously, and specific harmonic orders are programmable.
Harmonic compensation, reactive power compensation and three-phase unbalance compensation.
Communication protocol: the power of the general protocol, Modbus protocol, TCP/IP
Fault alarm and recording function, can be as much as 500 alarm records.
With all kinds of complete and effective protection measures, such as over-voltage protection, under voltage protection, short circuit protection, inverter bridge reverse protection, compensation protection etc.
Protection grade: IP20, the remaining IP grade can be customized
Human-friendly LCD displaying all voltage, current and harmonic data in numerical, waveform and spectrum. Log record is available.
 
Specification Sheet
Model Output
Current
(A)
Electrical
Wiring
Net Weight(kg) Structure
APFM0.4-35/3(4)a 35 3 phase,3 wires/3 phase,4 wires 32
Wall Mounted
 
APFM0.4-50/3(4)a 50 3 phase,3 wires/3 phase,4 wires 32
APFM0.4-60/3(4)a 60 3 phase,3 wires/3 phase,4 wires 40
APFM0.4-100/3(4)a 100 3 phase,3 wires/3 phase,4 wires 45
APFM0.4-150/3(4)a 150 3 phase,3 wires/3 phase,4 wires 48
APFM0.4-35/3(4)b 35 3 phase,3 wires/3 phase,4 wires 32
Rack Type
APFM0.4-50/3(4)b 50 3 phase,3 wires/3 phase,4 wires 32
APFM0.4-60/3(4)b 60 3 phase,3 wires/3 phase,4 wires 40
APFM0.4-100/3(4)b 100 3 phase,3 wires/3 phase,4 wires 45
APFM0.4-150/3(4)b 150 3 phase,3 wires/3 phase,4 wires 48


Advantages:
Optimize your harmonic filtering efficiency: the 3-Level Topology Design Approach 
Active harmonic filters are based on power electronic technology, designed for mitigating harmonics injected by non-linear loads in power networks, generally installed in parallel to the polluting loads. The active filters analyze the line current harmonics drawn by the loads and generate a compensation current at the opposite phase angle, thereby "neutralizing" the harmonic currents.
Optimized harmonics filtering efficiency
Selection of every harmonic to the 50th order /Filter up to 50th harmonics simultaneously /Harmonic filtering levels [%] for each specific harmonic order can be pre-configured / Resonance protection by means of pre-configuring harmonic filtering levels for the potential resonance zones / Harmonic attenuation > 97%
Compact high performance
Ultra-compact, space economical / User-friendly, ease of commissioning / Parallel capability of modular AHF units with respect to network requirements / Available in rack, wall mounting designs and complete enclosure type
Enhanced Reliability Levels
Incorporates intelligent FFT calculation method:
Provides "real time sensing" of network impedance for progressive harmonics compensation to achieving system stability
Advanced control algorithm for resonance protection
In event of parallel resonance with load variations, the APF is designed to assess and "shut-down" to avoid equipment damage
Unique modular design. 
Each module works independently both in wall and rack mount type, easy for logistics, installation and maintenance work.
Modular power ratings 35A/50A/60A/100A,  and unlimited combination in parallel.
The maximum capacity per cabinet can be 600A, especially used in applications where space is at a premium.
Current Source Active Filter with Control Cabinet Enclosures in Power Quality Improvement in 3 Phase System
Current Source Active Filter with Control Cabinet Enclosures in Power Quality Improvement in 3 Phase System
Current Source Active Filter with Control Cabinet Enclosures in Power Quality Improvement in 3 Phase System
Current Source Active Filter with Control Cabinet Enclosures in Power Quality Improvement in 3 Phase System
Current Source Active Filter with Control Cabinet Enclosures in Power Quality Improvement in 3 Phase System
Current Source Active Filter with Control Cabinet Enclosures in Power Quality Improvement in 3 Phase System
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours