High Precision Class 0.2s RS485 Modbus-RTU LCD Display Active Energy Power Meter

After-sales Service: 2 Years
Warranty: 2 Years
Display: Digital

Products Details

  • Overview
  • Overview
  • Product Parameters
  • Dimension
  • Wiring
Overview

Basic Info.

Model NO.
apm801
Installation
Indirect Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter, Panel Power Meter
Electric Equipment
Three-phase Four-wire
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Communication
RS485 Modbus-RTU
System Voltage
AC380V
Accuracy
0.5s Class
Current
5A CT Connet
Function
Real Time and Maximum Demand
Transport Package
Carton
Specification
0.5kg
Trademark
Acrel
Origin
China
HS Code
9028301400
Production Capacity
300000

Packaging & Delivery

Package Size
17.00cm * 15.00cm * 13.00cm
Package Gross Weight
2.000kg

Product Description

Overview

 

Overview
High Precision Class 0.2s RS485 Modbus-RTU LCD Display Active Energy Power Meter

     

APM series power meters of ACREL are power meters that are designed according to IEC standards and synchronized with
international advanced technology.
APM series meters have full power measurement, energy statistics, analysis of power quality and network communications and
other functions, are mainly used for comprehensive monitoring of the quality of power supply network.
This series of meters use a modular design, with a rich function of the external DI / DO module, AI / AO module, event recording
(SOE) module with T-Flash (TF) card, network communication module, Temperature and humidity measurement module, can
achieve full power measurement of electrical circuit and monitoring of switch status, Dual RS485 with Ethernet interface can realize data copying of RS485 master station, eliminating the need for data switching exchange. PROFIBUS-DP interface can realize
high-speed data transmission and networking function.

Product Parameters

Technical Parameters Index
Signal Electrical network Three-phase three-wire, three-phase four-wire, see the wiring diagram;
Frequency 45~65Hz;
Voltage Rated value:AC 100V,110V,400V,690V;
Overload: 1.2 times rated value(continuous); 2 times rated value /1 second;
Power consumption: < 0.5VA (per channel);
Current Rated value: AC 1A, 5A, support 4 mm2 line access;
Overload: 1.2 times rated value(continuous); 10 times rated value/1 second;
Power consumption: < 0.5VA (per channel);
Measurement accuracy Voltage,current and power class 0.5s/class 0.2s (APM800,APM810/APM801)
Active power class 0.5s/class 0.2s (APM800,APM810/APM801)
Reactive power class 2
Harmonic 1%(2rd~42nd),2%(43rd~63rd)
Switch inputs Dry contact inputs, built-in power supply;
Relay outputs Contact type: open contact in main part, changeover contact in module;
Contact capacity:AC 250V/3A  DC 30V/3A;
Pulse output of energy Output mode: Optocoupler pulse with open collector;
Pulse constant:4000(5A),8000(1A) imp/kWh;
Analog outputs DC 0mA~20mA,4mA~20mA,0V~5V,1V~5V output, accuracy class 0.5%, load resistance ≤ 500Ω;
Analog inputs DC 0mA~20mA,4mA~20mA,0V~5V,1V~5V iutput, accuracy class 0.5%
Storage card Standard Capacity:4G,TF Card Up to 32G Capacity;
Communication RS485 interface/Modbus-RTU protocol and DLT645 protocol
Profibus-DP interface/Profibus-DP protocol;
RJ45 interface (Ethernet) / Modbus-TCP, http, DHCP and other protocols;
Power supply Working range: AC/DC 85V~265V or AC/DC 115~415V(P2);
Power consumption: Power consumption of the main part ≤ 15VA;
Safety Power frequency withstand voltage The power frequency withstand voltage between the shell and the auxiliary power supply, each input and output terminal group is AC 4kV/1min;
The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC 2kV/1min;
The power frequency withstand voltage between the voltage input and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between the current input and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between the relay output and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between each terminal group of switch input, communication, analog output and pulse output is AC 1kV/1min;
Insulation resistance Inputs,outputs to the shell>100MΩ;
Electromagnetic compatibility Meet IEC 61000 standard (Level 4);
Protection level Display panel IP52
Environment Operating temperature: -20 °C ~ +65 °C;
Storage temperature: -20°C~+70°C;
Relative humidity: ≤95% without condensation;
Altitude: ≤2500m;
Standards IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
Environmental Testing-Part 2-1:Tests Test A:Cold IDA
Part 2-1:Tests Test B:Dry heat
Part 2-30:Tests Test Db:Damp heat,cyclic(12+12h)
IEC 61000-4 Electromagnetic compatibility-Testing and measurement techniques
IEC 61557-12 Electrical safety in low voltage distribution system up to 1000V a.c. and1500V d.c -Equipment for testing,measuring or monitoring of protective measures- Part12:
Performances measuring and monitoring devices(PMD)
 IEC 62053-22 Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2s and 0.5s)
 
Function APM800
(class 0.5s)
APM801
(class 0.2s)
APM810
(class 0.5s)
Measured parameters Total electrical measurement
Four-quadrant energy
Pulse output of energy Pulse output of active/reactive energy
Demand Three-phase current, active power, reactive power, real-time demand of apparent power, and maximum demand (including time stamp)
Extreme value statistics Extremum of current, line voltage, phase voltage, active power, reactive power, apparent power, power factor, frequency, total harmonic of current, total harmonic of voltage in this month and last month (including time stamp)
Power quality Unbalance of current, line voltage, phase voltage
Voltage phase angle, current phase angle
Voltage current phase Angle
Total (odd, even) harmonic content of voltage and current × ×
Harmonic content of voltage and current (2-63 times) × ×
Voltage crest factor × ×
Telephone waveform factor × ×
Current K-factor × ×
Alarm records A total of 66 kinds of alarm types, each type can record the most recent 16 alarm records, support extended records by TF card
Event log Record the most recent 128 event records, support extended records by TF card
Communication Modbus protocol
I/O 2 digital inputs + 2 digital outputs (2DI+2DO)
Extensions MD82 8 digital inputs + 2 digital outputs with changeover contacts (8DI+2DO)
MLOG TF card storage (alarm records, event records, electrical parameters and energy timing records, etc.)
MA84 8 analog inputs (class 0.5) + 4 analog outputs (class 0.5) (8AI+4AO)
MCM 1 RS485/Modbus-RTU, support master mode or slave mode
MCP 1 Profibus-DP
MCE 1 Ethernet, support Modbus-TCP, http, SMTP, DHCP protocol
  MTH 4 ways of temperature measurement, 1 way of temperature and humidity control
 

Dimension

 

Dimension
High Precision Class 0.2s RS485 Modbus-RTU LCD Display Active Energy Power Meter
 

Wiring

 

Wiring
High Precision Class 0.2s RS485 Modbus-RTU LCD Display Active Energy Power Meter High Precision Class 0.2s RS485 Modbus-RTU LCD Display Active Energy Power Meter
  
About Acrel
High Precision Class 0.2s RS485 Modbus-RTU LCD Display Active Energy Power MeterHigh Precision Class 0.2s RS485 Modbus-RTU LCD Display Active Energy Power MeterHigh Precision Class 0.2s RS485 Modbus-RTU LCD Display Active Energy Power Meter

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours